Research tool Model P1 Open source

Observed VNIR.
Candidate SWIR.

Abstract BridgeCheck retrieves a physics-grounded SWIR candidate from an absolute-reflectance VNIR leaf spectrum. It is designed for paired-measurement study planning—not sensor replacement or diagnosis.

Input
400–1000 nm measured VNIR
Output
1052–2400 nm model-derived candidate
Compute
Verified locally in your browser
Figure 01 Spectral bridge schema
Measured VNIR and model-derived SWIR schematic A solid green measured curve ends at 1000 nanometers. After a marked gap, a dashed violet model-derived curve continues to 2400 nanometers. 400 1000 1600 2200 2400 nm MEASURED MODEL-DERIVED 1000 1052

The 1000–1052 nm gap and the two data origins remain explicit.

Run the frozen bridge

Start with a documented example, or provide your own measured VNIR point spectrum.

Verifying frozen artifact…

Example spectra

One click loads and runs locally. Labels describe spectral geometry—not biology.

5 deterministic examples

Generated-bank examples are exact by construction; zero context error is not evidence of real-world accuracy.

Input / VNIR

VNIR point spectrum

Provided input
Coverage
400–1000 nm
Minimum
100 bands
Gap
≤ 10 nm
Unit
decimal fraction
Built-in test data CABO measured VNIR sample 151 bands · anonymized training-group median · not validation
Paste CSV spectrum wavelength_nm,reflectance

Strictly increasing wavelengths. Fractions, not percentages. Values are never clipped.

Use a local file Read on this device; never transmitted.
No spectrum loaded
Ctrl + Enter

Output / inferred

Candidate spectrum

No candidate generated

Select an example or provide a contract-valid measured VNIR spectrum.

The useful result and the failed gate

Reconstruction improved across three sources. Camera validity and downstream utility still failed.

StudyEvaluation unitReconstruction resultDecision
EXP-0123CABO 468 biological groups 61.98% lower MAE Development mechanism pass
EXP-0124NASA FFT 9 external sites 55.28% lower MAE External point-spectrum pass
EXP-0125HySpex cubes 46 plants · 230 cubes 49.83% lower aggregate MAE Camera + utility gate failed

Relative MAE reductions are reconstruction results, not gains in diagnosis, biology, or downstream task performance.

From candidate to evidence

  1. 01
    Generate

    Explore a separately typed candidate curve.

  2. 02
    Measure

    Acquire same-unit VNIR and real SWIR.

  3. 03
    Audit

    Compare against strong baselines by group.

  4. 04
    Test value

    Evaluate measured SWIR on untouched endpoints.

Separate companion / Linux CLI

Challenge the declared spectral route before external validation.

BandTrace challenges a declared sensor-to-model route, measures required-band output dependence on adequate probes, and compares routed response functions with declared training support. It keeps executable, spectral and biological evidence separate.

BandTrace does not run on this page. BridgeCheck sends it no inputs or generated bands, and it does not change BridgeCheck's evidence, output types or claim ceiling.

X3 Dependence observed

On frozen probes for the selected numeric output—not global causal use.

S3 Declared SRF support

Routed response functions fit declared support—not camera calibration.

T0 Biology not evaluated

No transport, accuracy, diagnosis, certificate or deployment approval.

X3 + S3 + T0 is the instrument-controlled reference result, not a promise that a submitted model or sensor will pass.